==Description==
 +
The CmpCalib command compares two files of calibrations (in general of the same camera).
 +
 
 +
Calibration parameters of a camera can not be directly compared, the command estimates a rotation to align the parameters. The output file Delta Calib.txt contains a function which gives the differences between the two sets of calibration as function of the radius and a grid which provides planimetric vector deviation between each rays directions.
 +
 
 +
===Syntax===
 +
The basic syntax requires 2 args :
 +
<pre>mm3d CmpCalib Calibration1 Calibration2 </pre>
 +
 
 +
* Calibration file corresponds to Ori-***/AutoCal_Foc-***.xml .
 +
 
 +
===Help===
 +
A basic help can be asked with
 +
<pre> mm3d CmpCalib -help </pre> <br>
 +
 
 +
Mandatory unnamed args :
 +
*string :: {Correlation mode (must be in allowed enumerated values)}
 +
*string :: {Full Name (Dir+Pattern)}
 +
*string :: {Orientation}
 +
 
 +
Named args :
 +
* [Name=Teta01] REAL
 +
* [Name=Teta02] REAL
 +
* [Name=Teta12] REAL
 +
* [Name=L1] INT
 +
* [Name=SzW] INT
 +
* [Name=DynV] REAL
 +
* [Name=Out] string :: {Result (Def=Name1_ecarts.txt)}
 +
* [Name=DispW] bool :: {Display window}
 +
* [Name=XmlG] string :: {Generate Xml}
 +
 
 +
 
 +
===Example===

Version du 22 octobre 2016 à 12:25

Picto-liste.png List of commands

Description

The CmpCalib command compares two files of calibrations (in general of the same camera).

Calibration parameters of a camera can not be directly compared, the command estimates a rotation to align the parameters. The output file Delta Calib.txt contains a function which gives the differences between the two sets of calibration as function of the radius and a grid which provides planimetric vector deviation between each rays directions.

Syntax

The basic syntax requires 2 args :

mm3d CmpCalib Calibration1 Calibration2 
  • Calibration file corresponds to Ori-***/AutoCal_Foc-***.xml .

Help

A basic help can be asked with

 mm3d CmpCalib -help 

Mandatory unnamed args :

  • string :: {Correlation mode (must be in allowed enumerated values)}
  • string :: {Full Name (Dir+Pattern)}
  • string :: {Orientation}

Named args :

  • [Name=Teta01] REAL
  • [Name=Teta02] REAL
  • [Name=Teta12] REAL
  • [Name=L1] INT
  • [Name=SzW] INT
  • [Name=DynV] REAL
  • [Name=Out] string :: {Result (Def=Name1_ecarts.txt)}
  • [Name=DispW] bool :: {Display window}
  • [Name=XmlG] string :: {Generate Xml}


Example